Torch Data 8-1 Manual 0-4821 Rev. AG
8. TORCH OPERATION
Torch Parts Selection
The application will determine which torch parts must be used. Refer to the cut charts for the proper torch parts to
install for a selected application.
CAUTION
Do not interchange parts. Make sure all torch parts correspond with the
plasma and shield gases in use for the application.
Pre-Setting Power Supply Controls
Set the Power Supply controls prior to operating the system as described in the power supply Operating Manual.
Refer to the cutting charts for the proper cutting parameters for the application.
Recommended Cutting Speeds
Cutting speed depends on material and thickness. The following factors may affect system performance:
Torch parts wear; gas quality and mass flow / pressure; operator experience; torch standoff height; proper
work cable connection; alloingy contents of material; cutting table capabilities & accuracy.
NOTE
This information represents realistic expectations using recommended
practices and well-maintained systems. Actual speeds may vary from
those shown in the charts depending on the alloy content of the selected
material. Voltage ratings may vary depending on the CNC, cutting table,
or height controller.
For complete cutting speed chart data refer to the following pages.
Consumables Notes
Always assemble the consumable parts properly. Improper assembly may damage the parts or the torch head.
Ensure that parts are seated together correctly.
Always check the shield gas distributor for charring when changing parts. Do not use the distributor if it is charred.
Replace the shield gas distributor regularly to ensure proper performance.
Operational Notes
Always purge the torch after changing consumables or if the power supply has been shut off. The power supply's
built-in purge function may not be enough to properly purge the torch. Manually flow gas with the 'Test Cut Flow' and
'Test Pre-Flow' functions to help remove any remaining coolant from the lines.
Slightly increasing the preflow pressure may increase piercing ability on thicker materials. However, increasing the
preflow pressure too much may affect plasma starting reliability (misfiring).
Decreasing preflow pressure may improve piloting. Preflow pressure can be reduced without affecting cut perfor-
mance as long as the pilot arc still transfers to the plate well. Decreasing preflow pressure too much will affect the
ability to transfer the arc to the plate and may cause damage to the tip.
Notes on Chart Measurements
Pressure measurements in the charts are in psi(g), not psi(a). 0 psi(g) = 14.7 psi(a) (1 atmosphere).
Ball settings are at the center of the guage ball.
Zobrazit stránku 0
1 2 3 4 5 6 ... 27 28

Shrnutí obsahu

Strany 1 - 8. TORCH OPERATION

Torch Data 8-1 Manual 0-4821 Rev. AG8. TORCH OPERATIONTorch Parts SelectionThe application will determine which torch parts must be used. Refer t

Strany 2 - Underwater Cutting

Torch Data 8-10 Manual 0-4821 Rev. AGStainless Steel100AAir Plasma / Air Shield(ga) (in) inch psi Ball psi Ball psi Volts(in)±0.005(ipm) (in) (sec)

Strany 3 - Mild Steel

Torch Data 8-11 Manual 0-4821 Rev. AG(ga) (in) inch (PSI) Ball (PSI) Ball (PSI) Volts(in)±0.005(ipm) (in) (sec) (in)3/8 0.375 40 65 120 59 120 148 0.

Strany 4 - Plasma / Air Shield

Torch Data 8-12 Manual 0-4821 Rev. AGStainless Steel100AN2 Plasma / H2O Shield(ga) (in) inch psi Ball* psi Ball* psi Volts(in)±0.005(ipm) (in) (sec

Strany 5

Torch Data 8-13 Manual 0-4821 Rev. AGStainless Steel200AAir Plasma / Air Shield35-101835-101935-128135-105735-108535-1020ShieldRetainerShield CupShie

Strany 6

Torch Data 8-14 Manual 0-4821 Rev. AGStainless Steel200AH35 Plasma / N2 Shield **(ga) (in) inch (PSI) Ball (PSI) Ball (PSI) Volts(in)±0.005(ipm) (i

Strany 7 - Art # A-07292

Torch Data 8-15 Manual 0-4821 Rev. AG(ga) (in) inch (PSI) (Ball) (PSI) (Ball) (PSI) Volts(in)±0.005(ipm) (in) (sec) (in)3/8 0.375 20 80 90 5 55 155 0

Strany 8 - Art # A-07293

Torch Data 8-16 Manual 0-4821 Rev. AGAluminum55AAir Plasma / Air Shield(ga) (in) inch psi Ball psi Ball psi Volts(in)±0.005(ipm) (in) (sec) (in)23

Strany 9 - Art # A-07294

Torch Data 8-17 Manual 0-4821 Rev. AGAluminum100AAir Plasma / Air ShieldCartridge35-1020Shield Cup35-1016Shield Cap35-1027Shield Gas Distributor35

Strany 10 - Art # A-07295

Torch Data 8-18 Manual 0-4821 Rev. AG(ga) (in) inch (PSI) Ball (PSI) Ball (PSI) Volts(in)±0.005(ipm) (in) (sec) (in)3/8 0.375 40 68 120 51 120 153 0.

Strany 11 - H35 Plasma / N

Torch Data 8-19 Manual 0-4821 Rev. AGCartridge35-1020Shield Cup35-1016Shield Cap35-1034Shield Gas Distributor35-1272Tip35-1053Plasma Gas Distributor3

Strany 12 - O Shield

Torch Data 8-2 Manual 0-4821 Rev. AGOhmic SensingOhmic sensing is not recommended with water shield. Water on the plate interferes electrically with

Strany 13 - Air Plasma / Air Shield

Torch Data 8-20 Manual 0-4821 Rev. AGAluminum200AAir Plasma / Air Shield(ga) (in) inch (PSI) Ball (PSI) Ball (PSI) Volts(in)±0.005(ipm) (in) (sec)

Strany 14 - Shield **

Torch Data 8-21 Manual 0-4821 Rev. AGAluminum200AH35 Plasma / N2 Shield **35-1273Shield Cup 35-1016Shield CapShield GasDistributorTip35-1058Art # A

Strany 15 - O Shield

Torch Data 8-22 Manual 0-4821 Rev. AG(ga) (in) inch (PSI) (Ball) (PSI) (Ball) (PSI) Volts(in)±0.005(ipm) (in) (sec) (in)1/2 0.500 20 100 90 5 55 168

Strany 16 - Air Plasma / Air Shield

Torch Data 8-23 Manual 0-4821 Rev. AGO-Ring, Cat. No. 8-0544Inner O-Ring (Cat. No. 8-0545) Location (Under Locking Ring)O-Ring, Cat. No. 8-0540Snap R

Strany 17

Torch Data 8-24 Manual 0-4821 Rev. AGQty. Description Catalog Number1 XT-301Torch Head Kit 35-10011 Torch Clamp Assembly 9-93361 Plasma Gas Hose 9-94

Strany 18

Torch Data 8-25 Manual 0-4821 Rev. AGConsumables Selection ChartMaterial Gases UsedConsumable Description200A 100A 55AElectrode35-1085 Air/Air35-1071

Strany 19 - Art # A-07301

Torch Data 8-26 Manual 0-4821 Rev. AGO-Ring Selection for Torch Consumable PartsArt # A-07248_AB35-103435-105135-106035-106935-1078O-Ring 9-9035O-Rin

Strany 20

Torch Data 8-27 Manual 0-4821 Rev. AGPATENT INFORMATIONXTTM-301 Plasma Cutting Torch PatentsThe following parts are covered under U.S. and Foreign Pa

Strany 21

Torch Data 8-28 Manual 0-4821 Rev. AGXTTM-301 Plasma Cutting Torch PatentsThe following parts are covered under U.S. and Foreign Patents as follows:C

Strany 22

Torch Data 8-3 Manual 0-4821 Rev. AGMild Steel55AAir Plasma / Air ShieldTip35-1272Electrode35-1025Shield Cap35-105135-106935-1020Shield Cup35-1016P

Strany 23 - TORCH REPLACEMENT PARTS

Torch Data 8-4 Manual 0-4821 Rev. AGMild Steel55AO2 Plasma / Air Shield(ga) (in) inch psi Ball psi Ball psi Volts(in)±0.005(ipm) (in) (sec) (in)21

Strany 24 - Art # A-06981

Torch Data 8-5 Manual 0-4821 Rev. AGMild Steel100AAir Plasma / Air ShieldCartridge35-1020Shield Cup35-1016Shield Cap35-1027Shield Gas Distributor35

Strany 25 - Auto-Cut-O2

Torch Data 8-6 Manual 0-4821 Rev. AGMild Steel100AO2 Plasma / Air Shield(ga) (in) inch psi Ball psi Ball psi Volts(in)±0.005(ipm) (in) (sec) (in)16

Strany 26 - Art # A-07248_AB

Torch Data 8-7 Manual 0-4821 Rev. AGMild Steel200AAir Plasma / Air Shield(ga) (in) inch psi Ball psi Ball psi Volts(in)±0.005(ipm) (in) (sec) (in)1

Strany 27 - PATENT INFORMATION

Torch Data 8-8 Manual 0-4821 Rev. AGMild Steel200AO2 Plasma / Air Shield(ga) (in) inch (PSI) Ball (PSI) Ball (PSI) Volts(in)±0.005(ipm) (in) (sec)

Strany 28

Torch Data 8-9 Manual 0-4821 Rev. AGStainless Steel55AAir Plasma / Air Shield(ga) (in) inch psi Ball psi Ball psi Volts(in)±0.005(ipm) (in) (sec) (